6544Fermer6546
squalylLe 23/12/2009 à 18:45
>apdu 0010f000 06 010203040506 06
=> 0000: 00 10 F0 00 06 
   0005: 01 02 03 04 05 06 06 
have incoming data
p3=6
vdata.length=12
apdu is case 4 (both directions, will require get response)
sending header, len=5
waiting for a procedure byte
proc byte: 10
got an ACK for all remaining data bytes
Sending data bytes:6
waiting for a procedure byte
proc byte: 61
this was SW1
sw2 = 06
Command has response data, send a GET RESPONSE
sending header, len=5
waiting for a procedure byte
proc byte: C0
got an ACK for all remaining data bytes
Receiving data bytes:6
waiting for a procedure byte
proc byte: 90
this was SW1
sw2 = 00
(0.0 ms)
<= 0000: F1 F2 F3 F4 F5 F6 90 00 
>
j'ai réussi à réimplementer le protocole T=0 des cartes à puces avec le pic qui m'a cramé le doigt \o/